36 CFR Part 1194 - Proposed Information and Communication Technology (ICT) Standards and Guidelines NPRM - Preamble
407.12.3.2.2 Knee and Toe Space (Section-by-Section Analysis)
This section proposes dimensions for knee and toe space under ICT when an obstructed forward reach is provided. The dimensions necessary to accommodate the full knee and toe space under ICT would be 27 inches high minimum, 25 inches deep maximum, and 30 inches wide minimum. This knee and toe space would also have to be clear of obstructions. These dimensions and their resulting geometry are consistent with the ADA and ABA Accessibility Guidelines (36 CFR Part 1191, Appendix D, sections 306 and 308).
There are two proposed exceptions to this knee and toe space requirement. First, toe space with a reduced clear height of 9 inches (rather than 27 inches) would be permitted for a depth of no more than 6 inches. Building on this exception, the second exception would allow further reduction in the height of the space along the profile of the knee to the toe sloping at 6:1 toward the maximum protrusion of the ICT. This means that, for every 6 inches of height, the line can move toward the maximum protrusion of the ICT up to 1 inch or, put another way, 6 inches of rise to 1 inch of run. These two exceptions allow ICT to provide space beneath operable controls for ICT for knees and toes, or a portion of knees and toes, depending on the location of the controls.
User Comments/Questions
Add Comment/Question