ABA Accessibility Standard for GSA Facilities Pocket Guide
404.2.4.1 Swinging Doors and Gates.
Swinging doors and gates shall have maneuvering clearances complying with Table 404.2.4.1.
Table 404.2.4.1 Maneuvering Clearances at Manual Swinging Doors and Gates
Type of Use | Minimum Maneuvering Clearance | ||
---|---|---|---|
Approach Direction | Door or Gate Side | Perpendicular to Doorway | Parallel to Doorway (beyond latch side unless noted) |
From front | Pull | 60 inches (1525 mm) | 18 inches (455 mm) |
From front | Push | 48 inches (1220 mm) | 0 inches (0 mm)1 |
From hinge side | Pull | 60 inches (1525 mm) | 36 inches (915 mm) |
From hinge side | Pull | 54 inches (1370 mm) | 42 inches (1065 mm) |
From hinge side | Push | 42 inches (1065 mm)2 | 22 inches (560 mm)3 |
From latch side | Pull | 48 inches (1220 mm)4 | 24 inches (610 mm) |
From latch side | Push | 42 inches (1065 mm)4 | 24 inches (610 mm) |
1. Add 12 inches (305 mm) if closer and latch are provided.
2. Add 6 inches (150 mm) if closer and latch are provided.
3. Beyond hinge side.
4. Add 6 inches (150 mm) if closer is provided.
Figure 404.2.4.1 Maneuvering Clearances at Manual Swinging Doors and Gates