608.2.3 Alternate Roll-In Type Shower Compartments.
Alternate roll-in type shower compartments shall be 36 inches (915 mm) wide and 60 inches (1525 mm) deep minimum clear inside dimensions measured at center points of opposing sides. A 36 inch (915 mm) wide minimum entry shall be provided at one end of the long side of the compartment.
Note: inside finished dimensions measured at the center points of opposing sides
Figure 608.2.3 Alternate Roll-In Type Shower Compartment Size and Clearance