Comparison: 2010 and 1991 ADA Standards for Accessible Design - Scoping Requirements

This document on scoping requirements and its companion document on technical requirements were created as references to understand the differences between the 1991 and the 2010 ADA Standards for Accessible Design. The documents only include sections of the Standards that are new or different.

These documents are intended as informal guidance; they have not been reviewed by any federal agencies.

207 Accessible Means of Egress

1991 Standards for Accessible Design

2010 Standards for Accessible Design

What’s New/Different

4.1.3(9) In buildings or facilities, or portions of buildings or facilities, required to be accessible, accessible means of egress shall be provided in the same number as required for exits by local building/life safety regulations. Where a required exit from an occupiable level above or below a level of accessible exit discharge is not accessible, an area of rescue assistance shall be provided on each such level (in a number equal to that of inaccessible required exits). Areas of rescue assistance shall comply with 4.3.11. A horizontal exit, meeting the requirements of local building/life safety regulations, shall satisfy the requirement for an area of rescue assistance.

Exception: Areas of rescue assistance are not required in buildings or facilities having a supervised automatic sprinkler system.

4.1.6(1)(g) In alterations, the requirements of 4.1.3(9), 4.3.10 and 4.3.11 do not apply.

207.1 General. Means of egress shall comply with section 1003.2.13 of the International Building Code (2000 edition and 2001 Supplement) or section 1007 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1).

Exceptions:
1. Where means of egress are permitted by local building or life safety codes to share a common path of egress travel, accessible means of egress shall be permitted to share a common path of egress travel.
2. Areas of refuge shall not be required in detention and correctional facilities.

Change: Scoping based on International Building Code (IBC) requirements.

 

207.2 Platform Lifts. Standby power shall be provided for platform lifts permitted by section 1003.2.13.4 of the International Building Code (2000 edition and 2001 Supplement) or section 1007.5 of the International Building Code (2003 edition) (incorporated by reference, see "Referenced Standards" in Chapter 1) to serve as a part of an accessible means of egress.

New