ADAAG:
* Wheelchair seating: Requirements triggered in any assembly area with fixed seating that seats four or more people. The number of wheelchair locations required depends upon the size of the assembly area. When the area has over 300 seats, there are requirements for dispersal of wheelchair seating. ADAAG also contains requirements for aisle seats without armrests (or with removable armrests) and fixed seating for companions located adjacent to each wheelchair seating area (§4.1.3(19)(a)).
* Assistive listening systems: Certain fixed seating assembly areas that accommodate 50 or more people or have audio-amplification systems must have permanently installed assistive listening systems. Other assembly areas must have permanent systems or an adequate number of electrical outlets or other wiring to support a portable system. A special sign indicating the availability of the system is required. The minimum number of receivers must be equal to four percent of the total number of seats, but never less than two (§4.1.3(19)(b)). UFAS:
* Wheelchair seating: No requirements for wheelchair seating are triggered, unless the assembly area has 50 or more seats. Seating must be dispersed and provide comparable lines of sight (§4.1.2(18)(a)).
* Assistive listening systems: Assembly areas with audio-amplification systems must have a listening system that serves a reasonable number of people, but at least two. If it has no amplification system or is used primarily as meeting or conference room, it must have a permanent or portable system. No special signs are required (§4.1.2(18)(b)).