2013 California Standards for Accessible Design Pocket Guide
11B-603 TOILET AND BATHING ROOMS
11B-603.2 Clearances.
Clearances shall comply with Section 11B-603.2.
11B-603.2.1 Turning space.
Turning space complying with Section 11B-304 shall be provided within the room.
11B-603.2.2 Overlap.
Required clear floor spaces, clearance at fixtures, and turning space shall be permitted to overlap.
11B-603.2.3 Door swing.
Doors shall not swing into the clear floor space or clearance required for any fixture. Other than the door to the accessible water closet compartment, a door in any position, may encroach into the turning space by 12 inches (305 mm) maximum.
[2010 ADAS] 603.2.3 Door Swing. Doors shall not swing into the clear floor space or clearance required for any fixture. Doors shall be permitted to swing into the required turning space.
Exceptions:
1. Reserved.
[2010 ADAS] 1. Doors to a toilet room or bathing room for a single occupant accessed only through a private office and not for common use or public use shall be permitted to swing into the clear floor space or clearance provided the swing of the door can be reversed to comply with 603.2.3.
2. Where the toilet room or bathing room is for individual use and a clear floor space complying with Section 11B-305.3 is provided within the room beyond the arc of the door swing, doors shall be permitted to swing into the clear floor space or clearance required for any fixture.
ETA Editor's Note
Limiting the encroachment of door swings into the wheelchair turning space, and lacking Exception 1 above allowed by 2010 ADAS, the 2013 CBC requirements pertaining to toilet or bathing room clearances are more stringent. Note also that Exception 2 was not allowed in previous editions of CBC.
11B-603.3 Mirrors.
Mirrors located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 40 inches (1016 mm) maximum above the finish floor or ground. Mirrors not located above lavatories or countertops shall be installed with the bottom edge of the reflecting surface 35 inches (889 mm) maximum above the finish floor or ground.
11B-603.4 Coat hooks, shelves and medicine cabinets.
Coat hooks shall be located within one of the reach ranges specified in Section 11B-308. Shelves shall be located 40 inches (1016 mm) minimum and 48 inches (1219 mm) maximum above the finish floor. Medicine cabinets shall be located with a usable shelf no higher than 44 inches (1118 mm) maximum above the finish floor.
[S.H.: For coat hooks, see Safe Harbor at Subsections 11B-308.3.1 & 11B-308.3.2] For shelves, see [S.H. 1125B.3]
[2010 ADAS] 603.4 Coat Hooks and Shelves. Coat hooks shall be located within one of the reach ranges specified in 308. Shelves shall be located 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the finish floor.
11B-603.5 Accessories.
Where towel or sanitary napkin dispensers, waste receptacles, or other accessories are provided in toilet facilities, at least one of each type shall be located on an accessible route. All operable parts, including coin slots, shall be 40 inches (1016 mm) maximum above the finish floor.
Exception: Baby changing tables are not required to comply with Section 11B-603.5.
ETA Editor's Note
The 2013 CBC 11B-603.5 limitation on the height of accessories at toilet rooms is more stringent than 2010 ADAS. At locations other than toilet rooms, they are equivalent.
11B-603.6 Guest room toilet and bathing rooms.
Toilet and bathing rooms within guest rooms that are not required to provide mobility features complying with Section 11B-806.2 shall provide all toilet and bathing fixtures in a location that allows a person using a wheelchair measuring 30 inches by 48 inches (762 mm by 1219 mm) to touch the wheelchair to any lavatory, urinal, water closet, tub, sauna, shower stall and any other similar sanitary installation, if provided.