Hello. Please sign in!

Note: This document or portion of document references a state or local code that aligns with the 2010 ADA Standards requirements.

11B-605.2 Height and depth.

Urinals shall be the stall-type or the wall-hung type with the rim 17 inches (432 mm) maximum above the finish floor or ground. Urinals shall be 13½ inches (343 mm) deep minimum measured from the outer face of the urinal rim to the back of the fixture.

Figure (a) is an elevation drawing of a wall hung type having the urinal rim 17 inches maximum above the floor with a minimum depth of 13 1/2 inches measured from the outer face of the rim to the back of the fixture.

(a) wall hung type

Figure (b) is an elevation drawing of a stall (floor) type having a minimum depth of 13 1/2 inches measured from the outer face of the rim to the back of the fixture.

(b) stall type

FIGURE 11B-605.2 HEIGHT AND DEPTH OF URINALS

[MORE INFO...]

*You must sign in to view [MORE INFO...]