Hello. Please sign in!

SETTLEMENT AGREEMENT BETWEEN THE UNITED STATES OF AMERICA AND HARRIS COUNTY, TEXAS

This document, portion of document or clip from legal proceedings may not represent all of the facts, documents, opinions, judgments or other information that is pertinent to this case. The entire case, including all court records, expert reports, etc. should be reviewed together and a qualified attorney consulted before any interpretation is made about how to apply this information to any specific circumstances.

Attachment A: Violations Identified in the United States' Letter of Findings (Sept. 29, 2014)

Polling place violations that can be remediated with temporary measures

American Legion Post, 708 E. Parker Road, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Building Entrance & Voting Area: The area in front of the exterior entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4)

Baytown Community Center, 2407 Market Street, Baytown, TX (Early Voting Location Only)

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a fire extinguisher and two hand sanitizers that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor (1991 ADA Stds 4.4.1; 2010 ADA Stds 307.2).

  • Voting Area: One side of the double leaf doors to the voting area does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

Burbank Elementary School, 216 Tidwell Road, Houston, TX

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Charlton Park Rec Center, 8200 Park Place Boulevard, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide as the curb ramp is in the designated access aisle (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

Church of the Living God Temple 1, 2110 E. Crosstimbers Street, Houston, TX

  • Please note that the interior was closed so the United States did not conduct a full survey.

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Building Entrance: One side of the double leaf doors (the wood doors and the gated doors) at the designated accessible entrance does not provide at least 32 inches clear passage width when the doors are open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

El Mesias United Methodist Church, 406 E. Rittenhouse Street, Houston, TX

  • Building Entrance: The area in front of the exterior entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Ernest F. Mendel Elementary School, 3735 Topping Street, Houston, TX

  • Sidewalks & Walkways: The designated accessible route from the parking to the building entrance is not at least 36 inches wide as a flower pot blocks the path of travel (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Hallways and Corridors & Voting Area: One side of the double leaf doors in the interior of the school on route to the voting area does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

Evelyn Thompson Elementary School, 220 Casa Grande Drive, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Faith Presbyterian Church, 2301 S. Houston Road, Pasadena, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Felix H. Morales Elementary School, 305 W. Harris Drive, Pasadena, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Fire Station #20, 6902 Navigation Boulevard, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Freeman Elementary School, 2323 Theta Street, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Galena Park Library, 1500 Keene Street, Galena Park, TX (Early Voting & Election Day Location)

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch as it contains a 1 inch change (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

Gallegos Elementary School, 7415 Harrisburg Boulevard, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Gardens Elementary School, 1105 East Harris Avenue, Pasadena, TX

  • Building Entrance: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

Garfield Elementary School, 10301 Hartsook Street, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Building Entrance: The area in front of the exterior entrance on the ramp contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Glenbrook United Methodist Church, 8635 Glen Valley Drive, Houston, TX

  • Please note that the interior was closed so we did not conduct a full survey.

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Hardy Senior Center, 11901 West Hardy Road, Houston, TX

  • Building Entrance: The area in front of the exterior entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Hallways & Corridors: Maneuvering clearance is blocked by a large magazine rack (1991 ADA Stds 4.2.4.1, 4.13.6; 2010 ADA Stds 305, 404.2.4).

Harris County Administrative Building, 1001 Preston, 1st Floor, Houston, TX (Early Voting Location Only)

  • Building Entrance: One side of the double leaf door at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

Henderson Elementary School, 1800 Dismuke Street, Houston, TX

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The running slope of the accessible route is greater than 5% (but does not comply with ramp standards including handrails (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2) and edge protection (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9)) (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Heritage Elementary School, 1225 TC Jester Boulevard, Houston, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Holy Name Church, 1912 Marion Street, Houston, TX (Early Voting Location Only)

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Houston Gulf Coast and Construction, 2704 Sutherland Street, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Ingrando Park Rec Center, 7302 Keller Street, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the sidewalk is not free of abrupt level changes over 1/2 inch as the ramp on the designated accessible route is missing concrete and is in disrepair (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

JC Mitchell Elementary School, 10900 Gulfdale Drive, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The cross slope in the designated accessible route is steeper than 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: Because of mud and puddles on the sidewalk, the designated accessible route from the parking to the building entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

John Harris Elementary School, 801 Broadway Street, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

JP Cornelius Elementary School, 7475 Westover Street, Houston, TX

  • Sidewalks & Walkways & Building Entrance: The ramp slope at the entrance is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Knights Inn, 12500 North Freeway, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Lindale Assembly of God Church, 504 Chaplin Street, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Looscan Elementary School, 3800 Robertson Street, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The accessible route through the parking lot is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Mary Walke Stephens Elementary School, 2402 Aldine Mail Route, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Meadow Creek Village Park Community Center, 5333 Berry Creek Drive, Houston, TX

  • Building Entrance: The area in the vestibule of the exterior entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Mountain Top Ministries, 8420 Almeda Genoa Road, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The temporary ramp used as the designated accessible route from the parking to the building entrance is not at least 36 inches wide (1991 ADA Stds 4.8.3; 2010 ADA Stds 405.5).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch as it contains a 5 inch change (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

  • Sidewalks & Walkways & Building Entrance: The ramp slope of the current, temporary ramp from the parking to the building entrance is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Neighborhood Center Inc Ripley House Campus, 4410 Navigation Boulevard, Houston, TX (Early Voting & Election Day Location)

  • Sidewalks & Walkways: The pedestrian route contains a drug disposal box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.4.1; 2010 ADA Stds 307.2).

North Shore Friends Church, 1013 Maxey Road, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Primera Iglesia Bautista de Pasadena, 612 E. Houston Avenue, Pasadena, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The designated accessible route from the parking to the building entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.5.2; 2010 ADA Stds 303.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route is steeper than 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1 inch) (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Ralph Goodman Elementary School, 9325 Deer Trail Drive, Houston, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1 1/2 inches) (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Raul Yzaguirre School for Success Tejano Center, 2950 Broadway Boulevard, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Hallways & Corridors & Voting Area: The pedestrian route from the entrance to the voting area and within the voting area contains television sets that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor (1991 ADA Stds 4.4.1; 2010 ADA Stds 307.2).

Red Bluff Elementary School, 416 Bearle Street, Pasadena, TX

  • Sidewalks & Walkways & Building Entrance: The designated accessible route to the only building entrance open on election day is not free of abrupt level changes over 1/2 inch as it contains three steps. Although there is an accessible entrance, it was locked on election day (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

Richard & Kitty Spence Elementary School, 1300 Gears Road, Houston, TX

  • Sidewalks & Walkways: The designated accessible route from the parking to the building entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

Rick Schneider Elementary School, 8430 Easthaven Boulevard, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

San Jacinto Girl Scout Imperial Valley Center, 15800 Imperial Valley Drive, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Scarborough Elementary School, 3021 Little York Road, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

Scroggins Elementary School, 400 Boyles Street, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

South Houston Intermediate School, 900 College Avenue, South Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

St. Anne de Beaupre Catholic Church, 2810 Link Road, Houston, TX

  • Building Entrance: One side of the double leaf door at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1 1/4 inches) (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

St. Francis Cabrini Parish Center, 10727 Hartsook Street, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The designated accessible route from the parking to the building entrance is not free of abrupt level changes over 1/2 inch in several places (1991 ADA Stds 4.5.2; 2010 ADA Stds 303.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

St. Paul AME Church, 1554 Gears Road, Houston, TX

  • Building Entrance: The area in front of the exterior entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Thomas Gray Elementary School, 700 West Street, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

William Booth Garden Apartments, 808 Frawley Street, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide as the curb ramps are in the middle of the current access aisle (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6). 

Woodland Lodge No 1157, 8337 Sweetwater Lane, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Building Entrance & Voting Area: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Woodland Park Community Center, 212 Parkview Street, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Building Entrance: Maneuvering clearance in front of the entrance is inadequate due to sloped sides of the walkway before the entrance (1991 ADA Stds 4.2.4.1, 4.13.6; 2010 ADA Stds 305, 404.2.4).

Polling places that cannot be remediated with temporary measures:

Cage Elementary School, 4528 Leeland Street, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

  • Sidewalks & Walkways & Building Entrance: The ramp slope at the entrance is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Emanuel Deliverance Temple of Refuge, 4718 Little Crest Road, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking & Sidewalks & Walkways: The parking lot and the walkway to the sidewalk are covered with grass and do not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

  • Sidewalks & Walkways & Building Entrance: The ramp slope at the entrance is greater than 1:12 (14.6%) (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Building Entrance & Voting Area: The area in front of the exterior entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance & Voting Area: The door at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

  • Building Entrance & Voting Area: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

  • Building Entrance & Voting Area: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

Greater Love Baptist Church, 6113 Jensen Drive, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways & Building Entrance: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch as it contains two steps (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

  • Building Entrance & Voting Area: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

  • Building Entrance & Voting Area: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

Jefferson Davis High School, 1101 Quitman Street, Houston, TX

  • Sidewalks & Walkways & Building Entrance: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch as it contains four steps (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

Scarsdale Civic Association Building, 12127 Teaneck Drive, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (6.2% to 7.1%) (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (5 inches) (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Expert Report of James L.E. Terry, Evan Terry Associates, LLC (August 9, 2018)

Alexander Deussen Park Senior Center, 12303 Sonnier Street, Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking & Sidewalk & Walkways: The parking lots and the walkways to the entrance contain gravel, a manhole cover, and grass and do not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 502.4).

  • Drop-off: The surface slope in the vehicle pull-up space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4).

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The pedestrian route contains a handrail extension that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (5 inches) (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Alice McKean Young Library, 5107 Griggs Road, Houston, TX

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The designated accessible route from the parking to the building entrance is not at least 36 inches wide (28 C.F.R. § 35.133; 1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains cords and a hand sanitizer that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor (28 C.F.R. § 35.133; 1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Galena Park Library, 1500 Keene Street, Galena Park, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Drop-off: The surface slope in the vehicle pull-up space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4).

  • Drop-off: There is no accessible route from the vehicle pull-up space to the entrance as there is no curb ramp provided from the vehicle pull-up space and access aisle to the sidewalk and route to the entrance (1991 ADA Stds 4.6.6, 4.7.1, 4.3.2; 2010 ADA Stds 206.2.1, 402.2, 503.3).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

Hardy Street Senior Citizens Center, 11901 West Hardy, Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking & Sidewalk & Walkways: The parking lot and the walkway to the entrance contain gravel and do not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 502.4).

  • Drop-off: The surface slope in the vehicle pull-up space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4).

  • Sidewalks & Walkways: The accessible routes from the parking lot and public sidewalk to the entrance are not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors & Voting Area: The pedestrian routes from the entrance to the voting area and within the voting area contain sloping sections of the walls that protrude more than 4 inches into the routes and the bottom of each section is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The cross slope on the exit ramp from the voting area exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.8.6; 2010 ADA Stds 405.3).

  • Sidewalks & Walkways: The ramps along the designated accessible route from parking and the public sidewalk to the entrance do not have level landings at the top of the ramps (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks & Walkways: The exit ramp along the designated accessible route does not have a level landing at the top and bottom of the ramp that are at least 60 inches long (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks & Walkways: The ramp on the designated accessible route from the public sidewalk to the entrance does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

  • Sidewalks & Walkways: The ramp on the route from the public sidewalk to the building and the exit ramp have vertical drop-offs on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Harris County Courthouse Annex 14 SE, 5737 Cullen Boulevard, Houston, TX

  • Parking: The surface slope in the access aisle of the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Drop-off: The surface slope in the vehicle pull-up space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4).

  • Drop-off & Sidewalks & Walkways: The access aisle of the designated accessible vehicle pull-up space and the walkway to the entrance contain gravel and do not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 503.4).

  • Sidewalks & Walkways: The temporary curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The temporary curb ramp used as the designated accessible route to the entrance is not at least 36 inches wide (1991 ADA Stds 4.7.3; 2010 ADA Stds 405.5).

  • Building Entrance: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch for at least 60 inches of depth (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

  • Building Entrance: The area in front of the exterior, alternate entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Hallways & Corridors: The pedestrian route is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Hallways & Corridors: The interior door cannot be opened with 5 pounds of force or less (1991 ADA Stds 4.13.11; 2010 ADA Stds 404.2.9).

  • Elevator: The elevator lacks audible signals in the hallways to indicate arrival and direction of elevator car (1991 ADA Stds 4.10.4; 2010 ADA Stds 407.2.2.1).

  • Elevator: The elevator lacks visual and audible signals within the elevator car to indicate the position of the car (1991 ADA Stds 4.10.13; 2010 ADA Stds 407.4.8).

Harris County Annex 57, 19818 Franz Road, Katy, TX

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: An object hangs over the pedestrian route lower than 80 inches (1991 ADA Stds 4.4.2; 2010 ADA Stds 307.4).

Harris County Clear Lake Park Rec Center, 4953-4999 East NASA Parkway, Seabrook, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

Tom Bass Community Center - Section 3, 15108 Cullen Boulevard, Houston, TX

  • Parking: The surface slope in the access aisle of the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Drop-off: The surface slope in the vehicle pull-up space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a drinking fountain that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Expert Report of Ken Schoonover, P.E., KMS Associates, Inc. (August 7, 2018)

A.B. Anderson Academy 7401 Wheatly St., Houston, TX

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the polling entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Anderson Elementary School, 6218 Lynngate Dr., Spring, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a counter and two drinking fountains that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Voting area: There is insufficient maneuvering clearance in front of check-in stations (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3).

B. T. Washington High School, 119 E. 39th St., Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The route was not at least 36 inches wide because it was obstructed by a locked gate (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

Burrus Elementary School, 701 E. 33rd St., Houston, TX

  • Sidewalks & Walkways: The accessible route from the public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The accessible route from the public sidewalk to the entrance does not provide stable, firm, and slip resistant surfaces as it was not continuous and contains grass (1991 ADA Stds 4.1.2(4), 4.5.1; 2010 ADA Stds 302.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The inaccessible entrance lacks signage directing voters to the accessible entrance (1991 ADA Stds 4.1.2(7)(c); 2010 ADA Stds 216.6).

  • Building Entrance: The alternate, accessible entrance is locked (28 C.F.R. § 35.133).

  • Hallways & Corridors: The interior door cannot be opened with 5 pounds of force or less (1991 ADA Stds 4.13.11; 2010 ADA Stds 404.2.9).

  • Hallways & Corridors: The pull side of the interior door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Candlelight Park Community Center, 1520 Candlelight Lane, Houston, TX

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: An object hangs over the pedestrian route lower than 80 inches (1991 ADA Stds 4.4.2; 2010 ADA Stds 307.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Cypress Point Baptist Church, Blue Lake Dr., Huffman, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Durham Elementary School, 4803 Brinkman St., Houston, TX

  • Parking: The access aisle was blocked (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502.2, 502.3).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The route was not at least 36 inches wide because it was obstructed by a locked gate (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Building Entrance: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance did not have level landing at the bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

Eiland Elementary School, 6700 N. Klein Circle Dr., Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The exterior route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

First New Hope Bible Church, W. Mount Houston Rd, Houston, TX

  • Parking: Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The ramp does not have handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

G. W. Carver Contemporary High School, 2100S. Victory Dr., Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Ginger McNabb Elementary School, 743 East Cypresswood Dr., Spring, TX

  • Sidewalks & Walkways: The designated accessible route is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Voting area: There is insufficient maneuvering space in front of the accessible voting machine (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3).

God's Grace Community Church, 1106W. Tidwell Rd., Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Voting Area: There is insufficient maneuvering clearance in front of the accessible voting machine (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3).

Highland Park Recreation Center, 3316 De Soto St., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Holiday Inn Houston Intercontinental, 15222 John F. Kennedy Blvd., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Humble Elementary School, 20252 Fieldtree Dr., Humble, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains an AED box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Immanuel United Church, 26501 Border St., Spring, TX

  • Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA 404.2.2, 404.2.3, 404.2.4).  

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

John F. Kennedy Elementary School, 400 Victoria Dr., Houston, TX

  • Sidewalks & Walkways: The designated accessible route has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Jones EC PK Center, Forest Point Dr., Humble, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

Memorial Hills Clubhouse, Briarcreek Blvd., Houston, TX

  • Parking: The surface in the designated accessible parking space and access aisle is damaged and uneven, is not level in all directions, and has a slope that exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking: The access aisle does not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 502.4).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Nitsch Elementary School, W. Mount Houston Rd., Houston, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

North Belt Elementary School, E. North Belt Dr., Humble, TX

  • Voting Area: The width of the route in the voting area was not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: There is no level landing at least 60 inches long and 60 inches wide where the ramp changes directions (1991 ADA Stds 4.8.4(3); 2010 ADA 405.7.4).

  • Sidewalks & Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Northwest Church of Christ, 67220 W. Tidwell Rd., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

  • Hallways & Corridors: An object hangs over the pedestrian route lower than 80 inches (1991 ADA Stds 4.4.2; 2010 ADA Stds 307.4).

Oak Forest Elementary School-Houston, 1401 W. 43rd St., Houston, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The route was not at least 36 inches wide because it was obstructed by a locked gate (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

Osborne Elementary School, Ringold St., Houston, TX

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

River Pines Elementary School, 2400 Cold River Dr., Humble, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Salyers Elementary School, 25705 W. Hardy Rd., Spring, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope in the access aisle of the designated accessible van space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Spirit of the Word, 803 Curtin St., Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

St. Pius X High School, 811 W. Donovan St., Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The accessible route from the public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

Teague Middle School, 21700 Rayford Rd., Humble, TX

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Wesley Elementary School, Dillard St., Houston, TX

  • Sidewalks & Walkways & Entrance:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (2010 ADA Stds 303.4, 405.2).

Expert Report of John Rife Torkelson, theACCESSpartnership, L.P. (August 8, 2018)

Alvin D. Baggett Community Center, 1302 Keene St., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope of the designated accessible van space exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways:  The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Voting Area: The pedestrian route within the voting area contains a thermostat that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Beneke Elementary School, 3840 Briarchase St., Houston, TX

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Bethany Baptist Church Fellowship Hall, 7304 Homestead Rd., Houston, TX

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a receipt desk with a counter that protrudes more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Bruce Elementary School, 511 Jensen Dr., Houston, TX

  • Parking: The surface slope of the access aisle of the designated accessible van space exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The route was not at least 36 inches wide because it was obstructed by a gate (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Creekside Park Junior High School, 8711 Creekside Green Dr., Houston, TX

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Voting Area: The pedestrian route within the voting area contains an AED box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Eastwood Academy Charter High School, 1315 Dumble St., Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Eickenroht Elementary School, 15252 Grant Point Rd., Houston, TX

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes from the parking lot and the public sidewalk to the entrance exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Fiesta Mart Inc., 8130 Kirby Rd., Houston, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

First Baptist Church of Tomball, 401 Oxford St., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope of the access aisle and parking space exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Freeman Branch Library, 16616 Diana Ln., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes from the vehicle pull-up space and the public sidewalk to the entrance exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Gloria B. Sammons, 2301 Frick Rd., Houston, TX

  • Parking: The parking lot does not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 502.4).

  • Sidewalks & Walkways: The designated accessible route does not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Greater True Vine Missionary Baptist Church, 3011 Fontinot St., Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes from the parking and public sidewalk exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance:  One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA 404.2.2, 404.2.3, 404.2.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a drinking fountain that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Helen Major Elementary School, 16855 Sugar Pine Dr., Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Helms Community Learning Center, 503 West 21st St., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks &Walkways: The accessible route from the public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Hill Intermediate School, 2625 West Mount Houston St., Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Drop-off: The surface slope in the access aisle next to the vehicle pull-up space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The slopes of the ramps are greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The cross slope of the south ramp in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.8.6; 2010 ADA Stds 405.3).

  • Sidewalks & Walkways: The ramps along the designated accessible route to the entrance do not have level landings at the top of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

Hiram Clarke Multi Service Center, 3810 W. Fuqua St., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The route was not at least 36 inches wide because it was obstructed by a locked gate (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains an AED box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

John Phelps Courthouse, 101 South Rickey St., Houston, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes from the parking lot and public sidewalk exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Julia C. Hester House, 2020 Solo St., Houston, TX

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Justice of the Peace Entry, 5300 Griggs Rd., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The accessible routes from the parking lot and public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Voting Area: The width of the route in the voting area was not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

Kashmere Multi Service Center, 4802 Lockwood Dr., Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes from the public sidewalk and public transportation stop to the entrance exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains an AED cabinet that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have level landing at the bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

Key Middle School, 4000 Kelley St., Houston, TX

  • Parking: The surface slope in the designated permanent van accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking: The designated, temporary accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The accessible route from the public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Voting Area: The pedestrian route within the voting area contains a fire alarm pull box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have a level landing at the top that is at least 60 inches long (1991 ADA Stds 4.8.4(2); 2010 ADA 405.7.3).

Kyle Chapman Activity Center, 7340 Spencer Highway, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Lakes of Northpointe Clubhouse, 13502 Northpointe Ridge Ln., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Voting Area: The pedestrian route within the voting area contains a kitchen counter that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Langwood Baptist Church, 4134 Sutherland Rd., Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking & Sidewalk & Walkways: The parking lot and the walkway to the entrance contain gravel and do not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 502.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a shelf that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Londonberry Clubhouse, 8331 London Way Dr., Houston, TX

  • Parking: The parking lot contains mats covering gaps in the pavement that do not provide stable, firm, and slip resistant surfaces as they can be compressed into the gaps when pressure is applied (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 502.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The walkway from the parking lot to the entrance contains mats covering gaps in the pavement that do not provide stable, firm, and slip resistant surfaces as they can be compressed into the gaps when pressure is applied  (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Moody Park Community Center, 3725 Fulton St., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Neighborhood Centers Inc Ripley House, 4410 Navigation Blvd., Houston, TX

  • Sidewalks & Walkways: The accessible route from the public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a video phone that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Northbrook Senior High School, 1 Raider Circle South, Houston, TX

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Voting Area: The pedestrian route within the voting area contains a fire alarm pull box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Pleasantville Elementary School, 1431 Gellhorn Dr., Houston, TX

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Saint Timothy Lutheran Church, 14225 Hargrave Rd., Houston, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Scarsdale County Annex, 10851 Scarsdale Blvd., Houston, TX

  • Parking: The surface slope in the access aisle of the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains two fire extinguishers that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Sunnyside Multi-Purpose Center, 9314 Cullen Blvd., Houston, TX

  • Sidewalks & Walkways:  The designated accessible routes from the parking lot and public sidewalk to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the accessible routes from the parking lot and public sidewalk to the entrance exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains an AED cabinet and two hand sanitizers that protrude more than 4 inches into the route and the bottom of each object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Tomball City Hall Council Chamber, 401 Market St., Houston, TX

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a counter that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The ramp used as the designated accessible route is not at least 36 inches wide (1991 ADA Stds 4.8.3; 2010 ADA Stds 405.5).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have level landing at the top of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks & Walkways: There is no level landing provided for every 30 inches of rise of the ramp (1991 ADA Stds 4.8.4, 4.8.2; 2010 ADA 405.7, 405.6).

  • Sidewalks & Walkways: There is no level landing at least 60 inches long and 60 inches wide where the ramp changes directions (1991 ADA Stds 4.8.4(3); 2010 ADA 405.7.4).

 
Wesley United Methodist Church, 7225 Homestead Rd., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The parking lot contains gravel and does not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1, 502.4).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The slope in the maneuvering clearance in the vestibule of the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the interior vestibule door exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp since the element present had a gripping surface of 3 ½ inch height and 1 ½ inch width (1991 ADA Stds 4.8.5, 4.26.2, Fig. 39; 2010 ADA Stds 405.8, 505.2, 505.7.2).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

West Gray Adaptive Recreation, 1475 West Gray St., Houston, TX

  • Parking: The permanent and temporary designated accessible van spaces do not include access aisles that are at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slope in the access aisle of the designated accessible parking space in the back parking lot is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The accessible route from the public transportation stop to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: An object hangs over the pedestrian route lower than 80 inches (1991 ADA Stds 4.4.2; 2010 ADA Stds 307.4).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Exit: The automatic opener of the exit door is not operational, and the push side of the exit door does not provide at least 12 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

  • Building Exit: The raised threshold at the exit door exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have level landing at the top of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Wildwood Creek Elementary School, 13802 Northpoint Blvd., Houston, TX

  • Sidewalks & Walkways: The accessible route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Willow Creek Elementary School, 18302 North Eldridge Pkwy., Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Expert Report of Jeromy G. Murphy, American Construction Investigations, LTD (August 6, 2018)

Alice Johnson Junior High School, 15500 Proctor Street, Channelview, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Baldwin Boettcher Branch Library, 22248 Aldine Westfield Rd, Humble, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Drop-off: There is no accessible route from the vehicle pull-up space to the entrance as there is no curb ramp provided from the vehicle pull-up space and access aisle to the sidewalk and route to the entrance (1991 ADA Stds 4.6.6, 4.7.1, 4.3.2; 2010 ADA Stds 206.2.1, 402.2, 503.3).

  • Drop-off & Sidewalks & Walkways: The ramp slope of the designated accessible route from the vehicle pull-up space to the entrance is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

Cedar Bayou Junior School, 2610 East Elvinta Street, Baytown, TX

  • Drop-Off: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA 404.2.2, 404.2.3, 404.2.4).

Champion Life Center, 3031 FM 2920 Rd, Spring, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways & entrance:  The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

Champions Forest Baptist Church (Cypress Creek), 4840 Strack Rd, Houston, TX

  • Parking: The surface slope in the access aisle of the designated accessible van space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Cimarron Elementary School GPISD, 816 Cimarron Street, Houston, TX

  • Drop-off: The surface slope in the vehicle pull-up space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4).

  • Sidewalks & Walkways: The accessible route from the public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have a level landing at the bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA 405.7).

  • Sidewalks & Walkways & Building Entrance: The ramp along the designated accessible route to the entrance does not have a level landing at the top because the landing is less than 60 inches long and the slope of the landing exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.13.6, 4.8.4, 4.8.4(2); 2010 ADA 404.2.4.4, 405.7, 405.7.3).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp that are 34 inches to 38 inches above the ramp surface (1991 ADA Stds 4.8.5(5); 2010 ADA Stds 405.8, 505.4).

Coady Baptist, 5606 Wade Road, Baytown, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Cobb Elementary School, 915 Dell Dale Street, Channelview, TX

  • Sidewalks & Walkways: There is no accessible route from the public sidewalk to the entrance, because the route requires passage across and up the vehicular drive with a running slope greater than 5% and a cross slope that exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.1.2(1), 4.3.2, 4.8.6; 2010 ADA Stds 206.2.1, 405.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route from the parking lot to the entrance exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrances: The slopes in the maneuvering clearances at the exterior entrances exceed 1:48, reducing the required depth to less than 60 inches (1991 ADA Stds 4.5.2, 4.13.6, 4.8.4(2); 2010 ADA Stds 305.2, 404.2.4.4, 405.7.3).

Crosby Branch Library, 135 Hare Rd, Crosby TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Drew Elementary School, 223 Red Oak Avenue, Crosby, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA 404.2.2, 404.2.3, 404.2.4).

East Park Baptist Church, 8602 Tidwell Road, Houston, TX

  • Sidewalks & Walkways: There is no accessible route from the public sidewalk to the entrance, because the route requires passage through grass, which is not stable, firm, and slip resistant (1991 ADA Stds 4.1.2(4), 4.5.1; 2010 ADA Stds 206.2.1, 302.1).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Faith Christian Center, 10118 Tidwell Road, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The surface slopes in the access aisles of the designated van accessible parking space are not level in all directions and exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Building Entrance: The designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5; 2010 ADA 404.2.3).

  • Sidewalks & Walkways: The temporary ramp used as the designated accessible route from the parking to the building entrance is not at least 36 inches wide (1991 ADA Stds 4.8.3; 2010 ADA Stds 405.5).

  • Sidewalks & Walkways: The width of the top landing of the temporary ramp used as the designated accessible route to the entrance is insufficient. (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7.2).

First Baptist Church of Jacinto City, 10701 Wiggins Street, Jacinto City, TX

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The slopes in the maneuvering clearances at the exterior entrances exceed 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Galena Park ISD Administration Building, 14705 Woodforest Blvd, Houston, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Greater True Light Baptist Church, 6828 Annunciation Street, Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sideways & Walkways: The pedestrian route contains air conditioning units that protrude more than 4 inches into the route and the bottom of the objects are more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The counter slope at the bottom of the curb ramp adjoining gutters and road surfaces is greater than 1:20 (1991 ADA Stds 4.7.2; 2010 ADA Stds 406.2).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Building Entrance: The inaccessible entrance lacks signage directing voters to the accessible entrance (1991 ADA Stds 4.1.2(7)(c); 2010 ADA Stds 216.6).

  • Sidewalks & Walkways & Building Entrance: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have a level landing at the top of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

Highlands Community Center, 604 Highland Woods Drive, Highlands, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Indian Shores Community Center, 20700 Block of Appaloosa Trail, Crosby, TX

  • Parking: The surface slope of the designated parking area exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The slope of the temporary ramp used as the designated accessible route from the parking to the building entrance is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The cross slope of the temporary ramp used as the designated accessible route from the parking to the building entrance exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.8.6; 2010 ADA Stds 405.3).

  • Sidewalks & Walkways: The temporary ramp used as the designated accessible route from the parking to the building entrance does not have a level landing at the bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

Jersey Village City Hall, 16327 Lakeview Dr, Jersey Village, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route from the public sidewalk to the entrance exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch because there is a surface opening greater than 1/2 inch adjacent to the threshold (1991 ADA Stds 4.13.8, 4.3.6, 4.5.4; 2010 ADA Stds 404.2.5, 403.2, 302.3).

Kingwood Branch Library, Bens View Ln., Kingwood, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Lone Star College- Atascocita Center, 15903 W. Lake Houston Pkwy, Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

North Channel Branch Library, Wallisville Rd, Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Northeast Multi-Service Center, 9720 Spaulding St., Bldg #4, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Drop-off: There is no accessible route from the vehicle pull-up space to the entrance as there is no curb ramp provided from the vehicle pull-up space and access aisle to the sidewalk and route to the entrance (1991 ADA Stds 4.6.6, 4.7.1, 4.3.2; 2010 ADA Stds 206.2.1, 402.2, 503.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Octavia Fields Branch Library, 1503 South Houston Ave, Humble, TX

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Prairie View A&M University – Northwest, 9449 Grant Rd, Houston, TX

  • Building Entrance: One side of the double leaf door at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

Expert Report of Douglas J. Anderson, RAS, CASP, LCM Architects (August 8, 2018)

Acres Homes Multi-Service Center, 6719 W. Montgomery Rd. Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a suggestion box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Bayland Park Community Center, 6400 Bissonnet St., Houston, TX

  • Parking: The surface slope in the access aisle of the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

Bear Creek Park Community Center, 3055 Bear Creek Park Drive, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Drop-off: The surface slope in the vehicle pull-up space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.6; ADA Stds 503.4)

  • Sidewalks & Walkways: The designated accessible route from the parking to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Sidewalks & Walkways: The cross slope on the exterior ramp exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.8.6; 2010 ADA Stds 405.3).

  • Sidewalks & Walkways: There is no level landing provided at the bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA 405.7).

  • Sidewalks & Walkways: There is no level landing at least 60 inches long provided for every 30 inches of rise of the ramp (1991 ADA Stds 4.8.4, 4.8.2; 2010 ADA 405.7, 405.6).

  • Sidewalks & Walkways: There is no level landing at least 60 inches long and 60 inches wide where the ramp changes directions (1991 ADA Stds 4.8.4(3); 2010 ADA 405.7.4).

  • Sidewalks & Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

Bella Vita Clubhouse, 1548 B N. Riviera Circle, Pearland, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The ramped portion of the sidewalk does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Carter G Woodson School, 10720 Southview Street, Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route contains a fire alarm pull box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Voting Area: There is insufficient maneuvering clearance in front of voting station (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3).

  • Voting Area: There is insufficient maneuvering clearance in front of the accessible voting machine (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3).

  • Hallways & Corridors & Voting Area: There is no level landing at least 60 inches long provided for every 30 inches of rise of the ramp (1991 ADA Stds 4.8.4, 4.8.2; 2010 ADA 405.7, 405.6).

Cloverland Park Community Center, 11800 Scott Street, Houston, TX

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Crestmont Park Community Center, 5200 Selinsky Road, Houston, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The accessible routes to the entrance are not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Golfcrest Elementary School, 7414 Fairway Drive, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Greater Lighthouse Church, 4514 Knoxville Street, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Building Entrance: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

  • Building Entrance: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4)

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Sidewalks & Walkways & Building Entrance: The ramp slope at the entrance is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways & Building Entrance: The ramp at the entrance has no level landing at the top (1991 ADA Stds 4.8.4; 2010 ADA 405.7).

Harris County Mud 81 Building, 805 Hidden Canyon Road, Katy, TX

  • Sidewalks & Walkways: The designated accessible route from the parking to the building entrance is not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes are steeper than 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Harris County Public Health Building, 2223 West Loop South Fwy, 1st Floor, Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The interior door cannot be opened with 5 pounds of force or less (1991 ADA Stds 4.13.11; 2010 ADA Stds 404.2.9).

  • Building Entrance: The inaccessible entrance lacks signage directing voters to the accessible entrance (1991 ADA Stds 4.1.2(7)(c); 2010 ADA Stds 216.6).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a medical drop-off box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

IBEW 66 Building, 4345 Allen Genoa Rd., Pasadena, TX

  • Sidewalks & Walkways: The slopes of the curb ramps are greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

James H. Law Elementary School, 12401 South Coast Drive, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The inaccessible entrance lacks signage directing voters to the accessible entrance (1991 ADA Stds 4.1.2(7)(c); 2010 ADA Stds 216.6).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains a fire alarm pull box that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Hallways & Corridors: The raised threshold at the interior door exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Jones Future Academy, 7414 Saint Lo Road, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The accessible route from the public sidewalk to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Hallways & Corridors: The pedestrian route is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Hallways & Corridors: Although there are stairs, no lift or elevator is provided (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 402.2).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

Juergen's Hall Community Center, 26026 Hempstead Hwy., Cypress, TX

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The inaccessible entrance lacks signage directing voters to the accessible entrance (1991 ADA Stds 4.1.2(7)(c); 2010 ADA Stds 216.6).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area contains coat hooks that protrude more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have a level landing at the top that is at least 60 inches long (1991 ADA Stds 4.8.4(2); 2010 ADA 405.7.3).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Katy Branch, Harris County Public Library, 5414 Franz Road, Katy, TX

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Liestman Elementary School, 7610 Synott Road, Houston, TX

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks & Walkways: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Living Faith Baptist Church, 4310 Holloway Drive, Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The designated accessible routes to the entrance are not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4)

  • Building Entrance: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

  • Building Entrance: The slopes in the maneuvering clearances at the exterior entrances exceed 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised thresholds at the two exterior entrances exceed 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Lone Star College - Cypress Center, 19710 Clay Road, Katy, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

Mahaney Elementary School, 13215 High Star Drive, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking: The designated van accessible parking space is not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

Martin Elementary School, 11718 Hendon Lane, Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The area in front of the exterior entrance contains a surface opening greater than 1/2 inch (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Voting Area: The width of the route in the voting area was not at least 36 inches wide (1991 ADA Stds 4.3.3; 2010 ADA Stds 403.5.1).

  • Voting Area: There is insufficient maneuvering clearance in front of the voting station (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3).

  • Voting Area: There is insufficient maneuvering clearance in front of the accessible voting machine (1991 ADA Stds 4.2.3; 2010 ADA Stds 304.3).

  • Sidewalks & Walkways: The cross slope of the ramp in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.8.6; 2010 ADA Stds 405.3).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have level landing at the bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Mayde Creek MUD Community Center, 19600 Misty Cove Drive, Houston, TX

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp that are 34 inches to 38 inches above the ramp surface (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.4).

Memorial Parkway Community Association Clubhouse, 21600 Cimarron Parkway, Houston, TX

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The ramp in the route from the parking lot to the entrance and the ramp in the route from the public sidewalk to the entrance have slopes greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The cross slopes of the ramp in the route from the parking lot to the entrance and the ramp in the route from the public sidewalk to the entrance exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.8.6; 2010 ADA Stds 405.3).

  • Sidewalks & Walkways: The ramp in the designated accessible route from the parking lot to the entrance does not have level landing at the bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks & Walkways: The ramp in the designated accessible route from the public sidewalk to the entrance does not have level landing at the top of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks & Walkways: There is no level landing at least 60 inches long and 60 inches wide where the ramp in the designated accessible route from the parking lot to the entrance changes directions (1991 ADA Stds 4.8.4(3); 2010 ADA 405.7.4).

  • Sidewalks and Walkways: The ramp in the route from the parking lot to the entrance and the ramp in the route from the public sidewalk to the entrance do not include handrails on each side of the ramps (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Reagan Webb Mading Elementary School, 8511 Crestmont Street, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The walkways are not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

Richard & Meg Weekley Community Center, 8440 Greenhouse Road, Cypress, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: One side of the double leaf doors at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA 404.2.2, 404.2.3, 404.2.4).  

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

South Belt Elementary School, 1801 Riverstone Ranch Road, Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

SPJST Lodge #88, 1435 Beall St., Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA 404.2.2, 404.2.3, 404.2.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

St. Philip Neri Catholic Church, 10960 Martin Luther King Blvd, Houston, TX

  • Parking: The designated van accessible parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The walkways are not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have level landing at the top of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Sunnyside Park Community Center, 3502 Bellfort Street, Houston, TX

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The ramped portion of the sidewalk does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Sylvan Rodriguez Jr. Elementary School, 5858 Chimney Rock Road, Houston, TX

  • Sidewalks & Walkways: The accessible route from the parking lot to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible routes to the entrance have surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The curb ramp slope in the designated accessible route from the parking lot to the entrance is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The curb ramp slope in the designated accessible route from the public sidewalk or public transportation stop to the entrance is greater than 1:12 (1991 ADA Stds 4.7.2, 4.8.2; 2010 ADA Stds 405.2, 406.1).

  • Sidewalks & Walkways: The cross slopes in the designated accessible routes exceed the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have level landing at the top and bottom of the ramp (1991 ADA Stds 4.8.4; 2010 ADA Stds 405.7).

The Crossing Community Church, 3225 W. Orem Drive, Houston, TX

  • Parking: The designated accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The interior door cannot be opened with 5 pounds of force or less (1991 ADA Stds 4.13.11; 2010 ADA Stds 404.2.9).

  • Sidewalks & Walkways: The ramp along the designated accessible route to the entrance does not have level landings at the top and bottom that are at least 60 inches long (1991 ADA Stds 4.8.4(2); 2010 ADA 405.7.3).

Tracy Gee Community Center, 3599 West Center Drive, Houston, TX

  • Parking: The surface slope in the designated accessible parking space and access aisle is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The designated accessible routes to the entrance are not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route from the parking lot to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: The cross slope in the designated accessible route from the parking lot to the entrance exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The slope in the maneuvering clearance at the exterior entrance exceeds 1:48 (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Sidewalks & Walkways: The ramp slope is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 303.4, 405.2).

  • Sidewalks & Walkways: The ramped portion of the sidewalk does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

Trini Mendenhall Community Center, 1414 Wirt Road, Houston, TX

  • Sidewalks & Walkways: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Sidewalks & Walkways: An object hangs over the pedestrian route lower than 80 inches (1991 ADA Stds 4.4.2; 2010 ADA Stds 307.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Hallways & Corridors: The pedestrian route from the entrance to the voting area a drinking fountain that protrudes more than 4 inches into the route and the bottom of the object is more than 27 inches above the floor (1991 ADA Stds 4.1.2(3), 4.4.1; 2010 ADA Stds 307.2).

Vincent Miller Intermediate School, 1002 Fairmont Pkwy, Pasadena, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Sidewalks & Walkways: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The designated accessible route to the entrance has surface openings greater than 1/2 inch (1991 ADA Stds 4.3.6, 4.5.4; 2010 ADA Stds 403.2, 302.3).

  • Building Entrance: The area in front of the exterior entrance contains a surface opening greater than 1/2 inch (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

Whidby Elementary School, 7625 Springhill Street, Houston, TX

  • Parking: The designated, temporary accessible van space does not include an access aisle that is at least 96 inches wide (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: The designated, temporary accessible van parking space was not located on the shortest accessible route to the accessible entrance (1991 ADA Stds 4.6.2; 2010 ADA Stds 208.3.1).

  • Sidewalks & Walkways: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303, 403.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).

  • Sidewalks & Walkways: The ramped portion of the sidewalk does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).