This document, portion of document or clip from legal proceedings may not represent all of the facts, documents, opinions, judgments or other information that is pertinent to this case. The entire case, including all court records, expert reports, etc. should be reviewed together and a qualified attorney consulted before any interpretation is made about how to apply this information to any specific circumstances.

Polling places that cannot be remediated with temporary measures:

Cage Elementary School, 4528 Leeland Street, Houston, TX

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

  • Sidewalks and Walkways: The exterior ramp does not include handrails on each side of the ramp (1991 ADA Stds 4.8.5; 2010 ADA Stds 405.8, 505.2).

  • Sidewalks & Walkways & Building Entrance: The ramp slope at the entrance is greater than 1:12 (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

Emanuel Deliverance Temple of Refuge, 4718 Little Crest Road, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking & Sidewalks & Walkways: The parking lot and the walkway to the sidewalk are covered with grass and do not provide stable, firm, and slip resistant surfaces (1991 ADA Stds 4.5.1; 2010 ADA Stds 302.1).

  • Sidewalks & Walkways: The ramp on the route to the building has a vertical drop-off on at least one side and no edge protection is provided (1991 ADA Stds 4.8.7; 2010 ADA Stds 405.9).

  • Sidewalks & Walkways & Building Entrance: The ramp slope at the entrance is greater than 1:12 (14.6%) (1991 ADA Stds 4.8.2; 2010 ADA Stds 405.2).

  • Building Entrance & Voting Area: The area in front of the exterior entrance contains no level landing (1991 ADA Stds 4.5.2, 4.13.6; 2010 ADA Stds 305.2, 404.2.4.4).

  • Building Entrance & Voting Area: The door at the designated accessible entrance does not provide at least 32 inches clear passage width when the door is open 90 degrees (1991 ADA Stds 4.13.4, 4.13.5, 4.13.6; 2010 ADA Stds 404.2.2, 404.2.3, 404.2.4).

  • Building Entrance & Voting Area: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

  • Building Entrance & Voting Area: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

Greater Love Baptist Church, 6113 Jensen Drive, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Sidewalks & Walkways & Building Entrance: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch as it contains two steps (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

  • Building Entrance & Voting Area: The exterior door lacks door hardware that is usable with one hand without tight grasping, pinching or twisting of the wrist (1991 ADA Stds 4.13.9; 2010 ADA Stds 309.4).

  • Building Entrance & Voting Area: The pull side of the entrance door does not provide at least 18 inches clearance to the side of the latch (1991 ADA Stds 4.13.6, Fig. 25; 2010 ADA Stds 404.2.4).

Jefferson Davis High School, 1101 Quitman Street, Houston, TX

  • Sidewalks & Walkways & Building Entrance: The designated accessible route to the entrance is not free of abrupt level changes over 1/2 inch as it contains four steps (1991 ADA Stds 4.3.8, 4.5.2; 2010 ADA Stds 303 and 403.4).

Scarsdale Civic Association Building, 12127 Teaneck Drive, Houston, TX

  • Parking: No accessible van space with an access aisle that is at least 96 inches wide is provided (1991 ADA Stds 4.1.2(5)(b), 4.6.3, Fig. 9; 2010 ADA Stds 502).

  • Parking: Signage for a van accessible parking space is not provided (1991 ADA Stds 4.6.4; 2010 ADA Stds 502.6).

  • Parking: The surface slope in the designated accessible parking space is not level in all directions and exceeds the maximum slope allowed of 1:48 (1991 ADA Stds 4.6.3; 2010 ADA Stds 502.4).

  • Sidewalks & Walkways: The cross slope in the designated accessible route exceeds the maximum slope allowed of 1:48 (6.2% to 7.1%) (1991 ADA Stds 4.3.7; 2010 ADA Stds 403.3).

  • Building Entrance: The raised threshold at the exterior entrance exceeds 1/2 inch (5 inches) (1991 ADA Stds 4.13.8; 2010 ADA Stds 404.2.5).